# 7. Finding a Known Material

**Goal:** go from "what is in this scene?" to "where is this specific
substance?" using WISER's four matching and unmixing tools, and know which one
to reach for.

**Data:** `caltech_15_20_22_bb.hdr` — a 20 × 22 pixel, 15-band short-wave
infrared (SWIR) subset (1308–1454 nm) carrying a **bad-band list**, so you can
see how flagged bands are dropped. Reference spectra from
`src/test_utils/test_spectra/usgs_resampHeadwallSWIR.hdr`.

```{note}
This cube is for practicing the mechanics of each tool. Its 1308–1454 nm range
straddles the 1400 nm water-vapor absorption, whose core is flagged bad. It
contains none of the features that identify minerals, so the results below are
not mineral identifications. Run the same steps on a full-range cube for real
ones.
```

**Reference:** {doc}`Spectral Angle Mapper
<../user-content/data-analysis-tools/spectral-angle-mapper>`, {doc}`Spectral
Feature Fitting <../user-content/data-analysis-tools/spectral-feature-fitting>`,
{doc}`Mixture-Tuned Matched Filter <../user-content/data-analysis-tools/mtmf>`,
{doc}`Linear Unmixing <../user-content/data-analysis-tools/linear-unmixing>`.

---

## Four tools, four questions

| Tool | Answers | Needs |
|---|---|---|
| **Spectral Angle Mapper (SAM)** | Which reference does this pixel most resemble in *shape*? | One or more reference spectra |
| **Spectral Feature Fitting (SFF)** | Do this pixel's *absorption features* match the reference's? | A reference *and* a diagnostic wavelength range |
| **Mixture-Tuned Matched Filter (MTMF)** | How much of this one target is present, against an unknown background? | One target spectrum |
| **Linear Unmixing** | What fraction of each of these known materials is in this pixel? | Endmembers for *every* material present |

The ordering is roughly "how much you have to know in advance". SAM asks the
least; unmixing asks the most and, in exchange, gives you abundances.

---

## Step 1 — Load the scene and collect spectra

1. Choose **File ▸ Open...** and select `caltech_15_20_22_bb.hdr`.
2. If the **Dataset Info** pane is not showing, click its pane toggle on the
   Main Toolbar. Expand the dataset, then expand **Bands (15)**. Bands 8 and 9
   (1348.5 and 1353.6 nm) end in **(bad)**: the header's bad-band list flags
   them. Every tool below drops them automatically.
3. If the **Spectrum Plot** pane is not showing, click its pane toggle.
4. Click three pixels that look different from each other, and click **Collect
   spectrum** after each, as in {doc}`Tutorial 2 <02-spectra>`. Steps 4 and 5
   use these as the MTMF target and as unmixing endmembers.

---

## Step 2 — Spectral Angle Mapper

SAM treats each spectrum as a vector in *n*-band space and measures the
angle between pixel and reference:

$$\theta = \arccos\!\left(\frac{\mathbf{p}\cdot\mathbf{r}}{\lVert\mathbf{p}\rVert\,\lVert\mathbf{r}\rVert}\right)$$

Because an angle depends only on direction, SAM ignores brightness. A
sunlit and a shadowed patch of the same mineral give the same small angle,
which is why it is the usual choice for scenes with topography or uneven
illumination. A smaller angle means a better match.

Choose **Tools ▸ Data Analysis ▸ Spectral Angle Mapper**.

:::{figure} ../_static/tutorials/t7_sam_dialog.png
:width: 90%
:align: center
:alt: The Spectral Angle Mapper dialog with a USGS mineral library as reference
:::

1. In the **Settings** section, set **Select Target Type:** to **Image Cube**
   (it starts on **Spectrum**), then pick your dataset from **Select Target:**
   beside it.
2. Set **Min Wavelength:** to `1308` and **Max Wavelength:** to `1454`, and
   leave **Units:** on **nm (nanometer)**. The fields start empty and the run
   will not start without them. Here the range covers the whole cube; on a
   full-range cube it decides whether you compare one absorption or everything
   at once.
3. **Reference Library Selection** already lists WISER's bundled
   `USGS_Mineral_Spectral_Library.hdr`, ticked. Click **Add Library**, select
   `src/test_utils/test_spectra/usgs_resampHeadwallSWIR.hdr`, and untick the
   bundled library, so the output has one band per Headwall reference. A
   library loaded in the Spectrum Plot does not appear in this list.
4. Leave **Initial Angle (°)** at its default of 5.
5. Click **Run SAM**.

Choosing **Spectrum** instead of **Image Cube** in the first step compares a
single spectrum against the references and returns a ranked table, which is a
fast way to identify a spectrum you just collected. Choosing individual
minerals and setting a separate threshold per reference are covered in
{doc}`Spectral Angle Mapper
<../user-content/data-analysis-tools/spectral-angle-mapper>`.

Two datasets come back, one band per reference:

- **`SAM Angle, Img: <source>`** — the angle in degrees at every pixel
- **`SAM CLS, Img: <source>`** — a boolean map of `angle < threshold`

Each band is named after its reference, such as
`Spec: kaolini1.spc Kaolinite CM9`. Switch
to the angle image with **Select dataset to view**, open the **Band chooser**,
select **Grayscale**, pick one mineral's band from **Grayscale Band**, and tick
**Use a colormap**. Set a stretch before trusting the classification.

```{admonition} Interpretation
:class: note
You choose the threshold, and the angle image shows you what that choice does. A
classification map only tells you which side of 5° each pixel fell on; the angle
image tells you whether a pixel was just over the line or nowhere near it.

Every reference is interpolated onto the target's wavelength grid before the
comparison, so a library resampled to a different sensor still works.
```

---

## Step 3 — Spectral Feature Fitting

SFF asks a narrower question: forget the overall spectrum, do the absorption
features line up?

It continuum-removes both spectra, dividing out the smooth upper envelope so
only the dips remain. It then inverts the result so absorptions become peaks,
and finds by least squares the single **scale factor** that best matches their
depths.

Choose **Tools ▸ Data Analysis ▸ Spectral Feature Fitting**. The inputs mirror
SAM's and are listed in
{doc}`Spectral Feature Fitting
<../user-content/data-analysis-tools/spectral-feature-fitting>`.

:::{figure} ../_static/tutorials/t7_sff_dialog.png
:width: 90%
:align: center
:alt: The Spectral Feature Fitting dialog
:::

1. Set the target type, dataset, wavelength range and library exactly as for
   SAM: **Image Cube**, your dataset, 1308 to 1454 nm, and the Headwall library
   added with **Add Library** in place of the bundled one. SFF continuum-removes
   over exactly this window.
2. Leave **Initial RMSE** at its default of 0.03.
3. Click **Run SFF**.

```{note}
**Set the wavelength range to bracket the feature you care about.** SFF over a
full spectral range averages your diagnostic band in with everything else. Over
a window around a known absorption it is far more specific than SAM. On a
full-range cube the usual targets are kaolinite 2160/2200 nm, alunite 2170 nm,
calcite 2340 nm, gypsum 1750 nm and chlorophyll 670 nm, all of which sit beyond
this tutorial's 1308–1454 nm subset, so here the window simply covers the whole
cube.
```

Three outputs, one band per reference:

- **`SFF RMSE, Img: <source>`** — root-mean-square fit error; lower is better
- **`SFF SCALE, Img: <source>`** — fitted feature depth, loosely an abundance
  indicator
- **`SFF CLS, Img: <source>`** — boolean `RMSE < threshold`

Read RMSE and SCALE together. A low RMSE with a near-zero scale is a good fit to
a feature that is not there.

---

## Step 4 — Mixture-Tuned Matched Filter

MTMF is for the case where you know your target but nothing about the
background, the usual situation in target detection.

:::{figure} ../_static/tutorials/t7_mtmf_dialog.png
:width: 55%
:align: center
:alt: The MTMF dialog showing input cube, noise method and target
:::

Choose **Tools ▸ Data Analysis ▸ Mixture Tuned Matched Filter**.

1. **Select Image Cube**: the dataset to search.
2. In the noise-method dropdown below it, choose **Image Cube Based**. It
   starts on **ROI Based**, which needs an ROI this scene does not have. Image
   Cube Based estimates noise from the scene itself; leave **Shift Diff
   Method** at **Shift Difference Down**.
3. **Target**: the spectrum to detect. The list holds the spectra you
   collected in Step 1, not library entries; choose one of them.
4. Click **OK**.

If you have a dark frame, or a region you know is background, the other two
noise methods use it instead. They are described in
{doc}`Mixture-Tuned Matched Filter <../user-content/data-analysis-tools/mtmf>`.

Internally MTMF runs a full MNF ({doc}`Tutorial 6 <06-pca-mnf>`) so the noise
is white, projects the target into that space, and computes a matched-filter
score per pixel: near 0 for background, near 1 for a pure target pixel. It also
computes each pixel's **infeasibility**: how far its spectrum is from any
physically plausible mixture of background and target.

```{note}
**A high score alone is not a detection.** The matched filter produces false
positives on spectra that happen to project well onto the target direction. The
mixture-tuning step separates them: a real detection has a high score and low
infeasibility. Scoring pixels without checking feasibility is the classic way
to over-report a target.
```

Two float32 datasets come back per target, both with nodata as `NaN`:
`MTMF [target]: <source>` holds the matched-filter score and
`IF [target]: <source>` holds the infeasibility. Read them together: a high
score is only believable where the same pixel in `IF` is low.

---

## Step 5 — Linear Unmixing

Unmixing assumes each pixel is a weighted sum of a few pure **endmember**
spectra and solves for the weights.

:::{figure} ../_static/tutorials/t7_unmix_dialog.png
:width: 55%
:align: center
:alt: The Linear Unmixing dialog with endmember list and Sum to Unity
:::

Choose **Tools ▸ Data Analysis ▸ Linear Unmixing**.

1. **Input Dataset**: the cube.
2. Click **Add Collected Spectrum** and pick at least two of the spectra you
   collected in Step 1. They make up the **Endmembers** list.
3. Optionally tick **Sum to Unity**. This softly forces each pixel's
   abundances to add to 1, which is right when you believe your endmembers
   cover everything in the scene and wrong when they do not.
4. Click **OK**.

The result carries one abundance band per endmember, in the order listed, plus
a final RMSE band.

```{note}
**Read the RMSE band first.** It is the per-pixel reconstruction error, and it
tells you where your endmember set fails to explain the data — usually because
a material is present that you did not include. Abundances in high-RMSE areas
are not meaningful.
```

Importing endmembers from a file, the **Sum to Unity** weight, and how bad
bands are handled are described in
{doc}`Linear Unmixing <../user-content/data-analysis-tools/linear-unmixing>`.

---

## Choosing between them

- You have a spectrum and want to know what it is → SAM in **Spectrum**
  mode against a library, then read the ranked table.
- You want a map of where a material is, illumination varies, and you have
  no background information → **SAM**, inspecting the angle image before
  thresholding.
- You know the diagnostic absorption and want specificity → **SFF** over a
  narrow window.
- You have one target, an unknown background, and want an abundance-like
  score → **MTMF**, checking feasibility.
- You have endmembers for everything and want fractions → **Linear
  Unmixing**, checking RMSE.

None of these tools proves a material is present. They rank pixels by how well
they match a hypothesis you supplied. Confirmation comes from the spectrum
itself. Go back to the Spectrum Plot, look at the pixels a tool flagged, and
check that the absorptions you expect are actually there.

---

## What you can now do

- Run all four matching and unmixing tools
- Pick the one that suits what you know going in
- Set a wavelength window around a diagnostic feature
- Read the diagnostic outputs (angle, RMSE, infeasibility) rather than only
  the classification

---

**Next:** {doc}`Tutorial 8 <08-bench-and-close-range>` takes the same tools to
a laboratory cube.