Spectral Feature Fitting (SFF)

Spectral Feature Fitting (SFF)#

SFF measures how well each pixel matches a reference spectrum by comparing their absorption features, the dips a material produces at characteristic wavelengths, rather than the overall spectrum.

How it works#

SFF isolates absorption features with continuum removal: it divides out the smooth “continuum” (the broad upper envelope of the spectrum), flattening the overall slope and brightness so only the absorption dips remain. The result is inverted (1 − continuum-removed) so each absorption band becomes a positive peak. This is done for both the pixel spectrum and the reference, over the chosen wavelength range.

SFF then fits the reference’s features to the pixel’s by finding a single scale factor (via least squares) that best matches their depths. Two numbers come out per pixel:

  • RMS error — the residual after fitting; how well the feature shapes agree. Lower RMSE means a better match, and an RMSE below the threshold marks a detection.

  • Scale — the fitted depth multiplier, a rough indicator of how strongly the feature is expressed (loosely, abundance).

Because it keys on absorption shape, SFF works best when you restrict the wavelength range to a known diagnostic feature. References are interpolated onto the target’s wavelength grid, and bad bands are dropped.

In Image Cube mode each run produces three datasets, one band per reference spectrum:

  • SFF CLS, Img: <source> — boolean classification (RMSE < threshold).

  • SFF RMSE, Img: <source> — the fit error at every pixel.

  • SFF SCALE, Img: <source> — the fitted scale (feature depth).

Each result keeps the source dataset’s georeferencing (map info and coordinate system), so a saved result opens in place in GIS software.

Using the tool#

The Spectral Feature Fitting dialog

Inputs work the same way as Spectral Angle Mapper:

  1. Target — choose Image Cube (or Spectrum) and select the dataset (or spectrum) to analyze.

  2. Wavelength range — set the min/max and units; for SFF this should bracket the absorption feature of interest.

  3. References — check one or more reference spectra. Add them via Add Library, Add Spectrum (from a text file), or Add Collected Spectrum; a default USGS mineral library is preloaded. Each reference has its own threshold (Initial RMSE, default 0.03), which starts at the method threshold and can be changed for each reference.

  4. Click Run SFF. Image-cube runs proceed in the background; spectrum runs open a ranked details table with a comparison plot.

See also#